p> BFR/BS Amount of bone formed per year on a given bone surface
4 - Static resorption parameters
Eroded surface/bone surface (%)
ES/BS Percentage of bone surface presenting a scalloped appearance
Osteoclast surface/Bone surface (%)
Oc.S/BS Percentage of bone surface covered by osteoclasts
-Aims of the study
The aim of the study was to assess locally specific numerical density of lacunes with a three-dimensional unbiased counting method and to analyze anisotropy of profiles of vascular canals in an embedded section of human tibia.
- Material and methods
- optical disector
- Delaunay triangulation
- bone biopsy
An undecalcified 150 micrometers thick transversal section was sawed from the diaphysis of tibia of a 70-year-old female, grinded to a 70-80 micrometers thick section, polished, stained with basic fuchsin, and observed with an optical microscope. We quantified numerical density of osteocyte lacunes in compact bone underlying the lateral, medial, and posterior surface. Image frames (n = 42) were sampled in an systematic uniform random manner from cortical and medullar layer round the tibial circumference. Each of the layers comprised one half of the local thickness of the bone section. Series of seven optical sections registered with respect to the Z-axis were photographed in each image frame. The unbiased counting rule of optical disector was applied to these series in order to assess the number of osteocyte lacunes per unit volume. Area fraction of the profiles of vascular canals in the bone sections was estimated with the point-counting method. Disector and point-grid counting was performed with the Ellipse software (ViDiTo, KoЕЎice, Slovak Republic). The two-dimensional anisotropy of profiles of vascular canals was assessed with the Delaunay triangulation (Qhull software, The Geometry Center, Minneapolis MN, USA). We carried out a 3-D reconstruction of vascular canal and surrounding lacunes in a part of a randomly selected Haversian system (software Amira, Mercury Computer Systems SAS, Merignac Cedex, France). p> Results numerical density of lacunes - anisotropy of vascular canals
Kruskal Wallis ANOVA did not prove significant differences (p = 0.051) in lacunar density among the bone areas underlying the lateral (18088 В± 2150 mm -3, mean В± SD), medial (16655 В± 3772 mm -3 ) and posterior surfaces (20222 В± 4109 mm -3 ). Lacunar density was higher (p = 0.032) in cortical (20356 В± 3725 mm -3 ) than in medullar layer (16287 В± 2274 mm -3 ). Area fraction of profiles of vascular canals was 10.5%. Delaunay triangulation of centres of gravity revealed considerable anisotropy in arrangement of profiles of vascular canals (N = 1194). The 2-D arrangement of vascular ca...